Quick overview of trigger I/Os of VC Smart Cameras

  VC20xx VC40xx VCSBC4018
IN 3 - 5 V 3 - 5 V 0 - 0.7 V low
1.5 - 3.3 V high
OUT Max. 7 V, 50 mA Max. 7 V, 50 mA Max. 3 V, 8 mA
Optocoupler IN: yes
OUT: no
IN: no
OUT: no
IN: no
OUT: no
Resistor IN: 330 limiting resistor
OUT: none
IN: none
OUT: none
IN: 4K7 pull-up resistor
OUT: none
Reverse voltage protection IN: shunt diode
OUT: none
IN: none
OUT: none
IN: none
OUT: none
Pin assignment
1 (green)
2 (brown)
3 (white)
4 (pink)
5 (grey)
6 yellow)

Trig IN -
5 V OUT
GND
Keypad IN
Trig OUT
Trig IN +

V24 OUT
5 V OUT
GND
V24 IN
Trig OUT
Trig IN
 
 