You are here: Service & Support / Knowledge Base/FAQ / VC20xx, VCSBC40xx, VC4xxx
Deutsch
English
Français
Japanese
Do you have a question?

Please contact us via email, contact form or phone
+49-7243-2167-23
(head office, Germany) or directly your local contact.

Special note

This knowledge base is updated regularly. If you need an information and don't find it here, please don't hesitate to contact us! Of course, we're also to your disposal at the phone:
+49 7243 2167-0

Trigger macros

Description of the fast trigger I/O macro functions

TRIGOUT_EXP(): sets the trigger output to exposure controlled mode. The trigger output is set automatically, according to the camera's trigger timings (see article "Trigger timings").

TRIGOUT_USR(): sets the trigger output to user controlled mode. The user can set the trigger output at will with SET_TRIGOUT() and RES_TRIGOUT().

SET_TRIGOUT(): sets the trigger output to active state.

RES_TRIGOUT(): resets the trigger output.

TRIGOUT_POS(): the trigger output is high in active state (during exposition in exposure controlled mode).

TRIGOUT_NEG(): the trigger output is low in active state (during exposition in exposure controlled mode).

TRIGINP_POS(): the trigger input signal is set to rising edge.

TRIGINP_NEG(): the trigger input is set to falling edge.

SET_trig_sticky(): see VCRT 5 documentation.

SET_trig_lossy(): see VCRT 5 documentation.

TRIG_INT_ENABLE(): enable trigger interrupt.

TRIG_INT_DISABLE(): disable trigger interrupt.

 